NFPA 25
Water Supply Tools
Hydrant and water supply tools for converting pitot readings, plotting supply curve points, and estimating available flow at required residual pressure.
4 tools1 tablesNFPA 25
Workflow tools
4
Interactive calculators
Standard context
NFPA 25
Primary engineering basis
Reference tables
1
Input setup support
Water Supply Tools workflow
Use this category page as a workflow control surface: confirm entry conditions, run the tools, review quality gates, and keep the records.
| Phase | Workflow step | Inputs | Outputs | Quality gate |
|---|---|---|---|---|
Phase 1 NFPA 25 | Enter hydrant test data, pitot pressure, outlet diameter, static pressure, and residual pressure. | Static pressure, Residual pressure, Test flow | Hydrant flow, Available flow, Supply curve point | Inputs have been checked against drawings, device listings, field test records, or project criteria. |
Phase 2 NFPA 25 | Calculate flow or available water supply using the visible test relationship. | Residual pressure, Test flow, Pitot pressure | Available flow, Supply curve point, Residual pressure check | Outputs including Hydrant flow, Available flow, Supply curve point, Residual pressure check have been reviewed before project use. |
Phase 3 NFPA 25 | Compare supply outputs against sprinkler demand and pump sizing screens. | Test flow, Pitot pressure, Outlet diameter | Supply curve point, Residual pressure check | Warnings, failed screens, or narrow margins are documented before moving to the next workflow. |
Entry conditions
- 1Use this workflow when the task belongs to water supply tools and the controlling project condition is known.
- 2Collect Static pressure, Residual pressure, Test flow, Pitot pressure before opening individual calculators.
- 3Confirm the values are project-specific, field-measured, manufacturer-listed, or selected from linked reference tables.
Records to keep
- 1Water Supply Tools input source checklist.
- 2Reviewed output set: Hydrant flow, Available flow, Supply curve point, Residual pressure check.
- 3Linked reference values used for the calculation basis.
- 4Next-step review note for final calculation package, field review, or submittal check.
Next steps
Reference tables for this workflow
Use
Use each calculator for screening and field checks before final project calculations.
Tools in this workflow
| Tool | Workflow role | Input basis | Primary outputs | Open |
|---|---|---|---|---|
Hydrant Flow Test NFPA 25 | Convert hydrant or flow test observations into water supply screening values. | Discharge coefficient, Outlet diameter, Pitot pressure | Hydrant flow | Open |
Pitot Flow NFPA 25 | Convert hydrant or flow test observations into water supply screening values. | Discharge coefficient, Outlet diameter, Pitot pressure | Hydrant flow | Open |
Available Water Supply NFPA 25 | Convert hydrant or flow test observations into water supply screening values. | Measured test flow, Static pressure, Residual pressure | Available flow | Open |
Water Supply Curve Plotter NFPA 25 | Convert hydrant or flow test observations into water supply screening values. | Measured test flow, Static pressure, Residual pressure | Available flow, Static pressure, Residual pressure | Open |